An M.2 solid-state drive can be installed in the storage drive
carrier, on the M.2 solid-state drive holder or on an M.2 solid-state
drive PCIe adapter.
M.2 solid-state drive in the storage drive bracket
To remove or install an M.2 solid-state drive, do the following:
Prepare your computer. See Preparing your computer and removing the computer cover.
To remove the failing M.2 solid-state drive, do the following:
Unlock the M.2
solid-state drive carrier with the provided key as shown. Store the
key in a secure place for later use. Press the eject button to eject
the carrier from the storage drive bracket. Then, grasp the M.2 solid-state
drive carrier by its edge and gently pull it out of the bracket.
Figure 1. Removing the M.2 solid-state drive carrier
Remove two screws
and slide the cover as shown to remove the cover from the carrier.
Figure 2. Removing the cover of the M.2 solid-state drive carrier
Loosen the screw
that secures the M.2 solid-state drive. Then, remove the M.2 solid-state
drive out of the slot at an angle of about 20 degrees.
Note: Do
not touch the circuit board of the M.2 solid-state drive.
Figure 3. Removing the M.2 solid-state drive
To install the M.2 solid-state drive, do the following:
Insert the new
M.2 solid-state drive into the slot at an angle of about 20 degrees.
Pivot the M.2 solid-state drive downward. Then, tighten the screw
to secure the M.2 solid-state drive.
Figure 4. Installing the M.2 solid-state drive
Reinstall the
cover of the carrier as shown and reinstall the screws to secure the
cover.
Figure 5. Installing the cover of the M.2 solid-state drive carrier
Reinstall the
carrier into the bracket as shown until it snaps in to position. Lock
the carrier with the key. Always store the key in a secure place.
Figure 6. Reinstalling the M.2 solid-state drive carrier
M.2 solid-state drive in the M.2 solid-sate drive
holder
To remove or install an M.2 solid-state drive in
the M.2 solid-sate drive holder, do the following:
Prepare your computer. See Preparing your computer and removing the computer cover.
Lay the computer on its side for easier access to the M.2 solid-state
drive slots.
Locate the M.2 solid-state drive slots. See Parts on the system board.
To remove the
M.2 solid-state drive holder, pivot the tab
1 upward to open
the latch
2 inside the multi-function bracket. Then, grasp
the M.2 solid-state drive holder by its edges and gently pull it out
of the M.2 solid-state drive slots.
Note:
The M.2 solid-state drive holder might fit tightly into the
M.2 solid-state drive slots. If necessary, alternately move each side
of the holder a small amount until it is removed from the slots.
Depending on the model, the M.2 solid-state drive holder might
look slightly different from the illustration.
Figure 7. Removing the M.2 solid-state drive holder
Turn the mounting
stud 90-degree counterclockwise to release the heat sink. Then, lift
the heat sink off the M.2 solid-state drive holder.
Figure 8. Removing the heat sink from the M.2 solid-state drive holder
To remove an
M.2 solid-state drive, do the following:
Loosen the screw that secures the M.2 solid-state drive 1.
Remove the M.2 solid-state drive with the screw holder from
the M.2 solid-state drive slot 2.
Remove the screw holder from the M.2 solid-state drive 3.
Figure 9. Removing the M.2 solid-state drive
To install an M.2 solid-state drive, do the following:
Align the notch
1 in the screw holder with the corresponding notch
2 in the M.2 solid-state drive. Insert the screw holder onto the new
M.2 solid-state drive as shown.
Figure 10. Inserting the screw holder onto the M.2 solid-state drive
Hold the new
M.2 solid-state drive by its edges and ensure that the circuit board
side is facing upward. Insert the drive into the corresponding slot
until it is firmly secured.
Note:
Pay attention to the direction of the notch 1 in the
new drive.
Do not touch the circuit board of the M.2 solid-state drive.
If only one M.2 solid-state drive is installed on the M.2 solid-state
drive holder, ensure that the drive is installed in the M.2 solid-state
drive slot 1 (20). See Parts on the system board.
Figure 11. Installing the M.2 solid-state drive
Tighten the screw
to secure the new M.2 solid-state drive.
Note: Do not overtighten the
screw.
Figure 12. Securing the M.2 solid-state drive
To install the M.2 solid-state drive heat sink, do the following:
If necessary, remove the film that protects the thermal pad
on the heat sink.
Insert two hooks
on the heat sink into the corresponding holes in the M.2 solid-state
drive holder as shown
1. Then, press the heat sink downward
2. Ensure that the mounting stud on the heat sink is inserted
into the hole in the M.2 solid-state drive holder.
Figure 13. Installing the heat sink onto the M.2 solid-state drive holder
Press the mounting
stud downward and press the mounting stud downward. Then, turn the
mounting stud 90-degree clockwise to secure the heat sink to the M.2
solid-state drive holder.
Figure 14. Securing the heat sink to the M.2 solid-state drive holder
To install the M.2 solid-state drive holder, do the following:
Align the notch
1 on the M.2 solid-state drive with the slot key
2 in
the M.2 solid-state drive slot. Then, slide the holder against the
multi-function bracket and press the holder downward until the M.2
solid-state drive is securely seated.
Note: Do not touch the circuit
board of the M.2 solid-state drive.
Figure 15. Installing the M.2 solid-state drive holder
Pivot the tab
1 downward until it snaps into position. Ensure that the latch
2 inside the multi-function bracket is closed.
Figure 16. Closing the card latch
M.2 solid-state drive in an M.2 solid-state drive
PCIe adapter
Install M.2 solid-state drives in the alphabetic order as shown.
Figure 17. M.2 solid-state drive installation order
To remove or install an M.2 solid-state
drive in the M.2 solid-state drive PCIe adapter, do the following:
Remove the M.2 solid-state drive PCIe adapter from the PCIe
card slot. See Full-length PCIe card.
Slide the cover
latches to the open position. Then, pivot the cover as shown until
it stops.
Figure 18. Opening the cover
Loosen the screws
that secure the M.2 solid-state drive heat sink. Then, remove the
heat sink as shown.
Figure 19. Removing the heat sink
To remove the
M.2 solid-state drive, pull the handle of the retention latch outward
to release the M.2 solid-state drive. Then, remove the M.2 solid-state
drive from the PCIe adapter.
Figure 20. Removing the M.2 solid-state drive
To install an M.2 solid-state drive, do the following:
If necessary,
move the retention latch to an appropriate location to suit the length
of the new M.2 solid-state drive.
Figure 21. Adjusting the location of the retention latch on the PCIe adapter
If necessary, remove the film on the thermal pad on which you
want to install the M.2 solid-state drive.
Pull the handle
of the retention latch outward to the open position.
Figure 22. Opening the retention latch
Hold the new
M.2 solid-state drive by its edges and ensure that the circuit board
side is facing upward. Insert the drive into the M.2 solid-state drive
slot on the PCIe adapter until it is firmly seated. Then, insert the
plug of the retention latch into the hole to secure the new drive.
Note: Do not touch the circuit board of the M.2 solid-state drive.
Figure 23. Installing the M.2 solid-state drive
Install the heat
sink as shown. Then tighten the screws to secure the heat sink.
Figure 24. Installing the heat sink onto the PCIe adapter
Install the cover
as shown. Then, slide the cover latches to the locked position.
Figure 25. Closing the cover
Install the M.2 solid-state drive PCIe adapter in a PCIe x16
card slot. See Full-length PCIe card.